资讯

精准传达 • 有效沟通

从品牌网站建设到网络营销策划,从策略到执行的一站式服务

vb.net以太网通信,vb网口通信

用vb.net实现网络通信

用 vb.net socket通信

我们提供的服务有:网站设计、成都网站制作、微信公众号开发、网站优化、网站认证、蒙自ssl等。为近1000家企事业单位解决了网站和推广的问题。提供周到的售前咨询和贴心的售后服务,是有科学管理、有技术的蒙自网站制作公司

Dim th As Threading.Thread

2 Dim tcpl As System.Net.Sockets.TcpListener

3

4 Private Sub Form1_Load()Sub Form1_Load(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Load

5 th = New System.Threading.Thread(New System.Threading.ThreadStart(AddressOf MyListen))

6 th.Start()

7 End Sub

8

9 Public Sub SendMessage()Sub SendMessage(ByVal IP As String, ByVal SendMsg As String)

10 Try

11 If IP "" Then

12 Dim tcpc As New System.Net.Sockets.TcpClient(IP, 5656)

13 Dim tcpStream As Net.Sockets.NetworkStream = tcpc.GetStream

14 Dim reqStream As New IO.StreamWriter(tcpStream)

15 reqStream.Write(SendMsg)

16 reqStream.Flush()

17 tcpStream.Close()

18 tcpc.Close()

19 End If

20 Catch ex As Exception

21 MsgBox(ex.Message.ToString)

22 End Try

23 End Sub

24 Private Sub MyListen()Sub MyListen()

25 Try

26 Dim ipAddress As System.Net.IPAddress = System.Net.Dns.Resolve(System.Net.Dns.GetHostName).AddressList(0)

27 tcpl = New System.Net.Sockets.TcpListener(ipAddress, 5656)

28 tcpl.Start()

29 While True

30 Dim s As System.Net.Sockets.Socket = tcpl.AcceptSocket()

31 Dim MyBuffer(1024) As Byte

32 Dim i As Integer

33 i = s.Receive(MyBuffer)

34 If i 0 Then

35 Dim lstrRec As String

36 Dim j As Integer

37 For j = 0 To i - 1

38 TextBox1.Text += Chr(MyBuffer(j)) ","

39 Next

40 End If

41 End While

42 Catch ex As Exception

43 MsgBox(ex.Message.ToString)

44 End Try

45 End Sub

46

47 Private Sub Button1_Click()Sub Button1_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles Button1.Click

48 SendMessage("192.168.0.61", TextBox2.Text)

49 End Sub

VB与VB.NET串口及以太网通迅

关于串口通讯的问题:

很明显,你还不知道(不会、不习惯)使用事件驱动的方式接收数据。

建议你仔细看看串口组件(无论VB6还是VB.net)的OnComm事件,你的问题很容易解决。

关于以太网通讯:

在TCP通讯中端口确实可以重用,你百度一下“TCP端口重用”能查到很多示例。

但绝大多数情况下不推荐端口重用,而应该采取服务器端建立连接池的方法。

或者,干脆不用TCP,用UDP解决也可以。

如何用vb.net通过以太网使用modulebus协议读写西门子s7-200 smart 能实现吗?

没用过modbus通信写过,但是使用自由通信可以

VB.net带有通信控件,在里面设置波特率、奇偶效验、数据位、COM口

在PLC里做个自由通信就可以

谁有VB和OMRON PLC 通信例子啊?能否发个原始代码? 再次特别感谢!

提供一个VB.NET与OMRON以太网通讯的代码,是我项目里面复制出来的:

Dim Handle1 As Int32 'PLC的连接句柄

Dim EntLink As Boolean '连接标志

Dim PLC As New FinsTcp.PlcClient '引用OMRON的通讯组件

Private Sub butLink_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butLink.Click

Dim re As Short

Dim restr As String = ""

re = PLC.EntLink(Trim(txtLocalIP.Text), Val(txtLocalPort.Text), Trim(txtRemoteIP.Text), Val(txtRemotePort.Text), "DEMO", Handle1)

txtReLink.Text = re.ToString

If re = 0 Then

EntLink = True

MsgBox("PLC联接成功! ")

Else

EntLink = False

MsgBox("PLC联接失败: "  restr)

End If

End Sub

Private Sub butClose_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butClose.Click

Dim re As Short

EntLink = False

re = PLC.DeLink(Handle1)

txtReClose.Text = re.ToString

End Sub

Private Sub butRead_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butRead.Click

Dim re As Short

Dim i As Short

Dim RD() As Object

ReDim RD(Val(txtReadCnt.Text - 1))

If Not EntLink Then

MsgBox("还未与PLC建立联接!")

Exit Sub

End If

Dim mry As FinsTcp.PlcClient.PlcMemory = cmbReadMry.SelectedIndex + 1

Dim typ As FinsTcp.PlcClient.DataType = cmbReadType.SelectedIndex + 1

re = PLC.CmdRead(Handle1, mry, typ, CUShort(Val(txtReadAdd.Text)), CUShort(Val(txtReadCnt.Text)), RD)

txtReRead.Text = re.ToString

lstRead.Items.Clear()

For i = 0 To UBound(RD) Step 1

If Not IsNothing(RD(i)) Then lstRead.Items.Add(RD(i))

Next i

If re  0 Then

Timer1.Enabled = False

butScan.Text = "Cycle R/W"

End If

End Sub

Private Sub butWrite_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles butWrite.Click

Dim re As Short

Dim i As Short

Dim temp() As String

Dim WD() As Object

If Not EntLink Then

MsgBox("还未与PLC建立联接!")

Exit Sub

End If

ReDim WD(Val(txtWriteCnt.Text) - 1)

temp = Split(txtWrite.Text, vbCrLf)

For i = 0 To UBound(WD) Step 1

If i  UBound(temp) Then

WD(i) = 0

Else

WD(i) = Trim(temp(i))

End If

Next i

Dim mry As FinsTcp.PlcClient.PlcMemory = cmbWriteMry.SelectedIndex + 1

Dim typ As FinsTcp.PlcClient.DataType = cmbWriteType.SelectedIndex + 1

re = PLC.CmdWrite(Handle1, mry, typ, CUShort(Val(txtWriteAdd.Text)), CUShort(Val(txtWriteCnt.Text)), WD)

txtReWrite.Text = re.ToString

If re  0 Then

Timer1.Enabled = False

butScan.Text = "Cycle R/W"

End If

End Sub